20A RCCB Circuit Breaker 4 Pole Earth Leakage Circuit Breaker G Type

20A RCCB Circuit Breaker 4 Pole Earth Leakage Circuit Breaker G Type

    • 20A RCCB Circuit Breaker  4 Pole Earth Leakage Circuit Breaker G Type
    • 20A RCCB Circuit Breaker  4 Pole Earth Leakage Circuit Breaker G Type
  • 20A RCCB Circuit Breaker  4 Pole Earth Leakage Circuit Breaker G Type

    Product Details:

    Place of Origin: WenZhou,China
    Brand Name: SEFIE
    Certification: IEC60898,CB,CE
    Model Number: SFL5-63

    Payment & Shipping Terms:

    Minimum Order Quantity: 2000-3000
    Price: Negotiable
    Packaging Details: 240pcs per carton,12pcs per box
    Delivery Time: 14 days after receipt of deposit
    Payment Terms: L/C, T/T
    Supply Ability: 200000pcs per month
    Contact Now
    Detailed Product Description
    Material: Plastic Pole: 2,4
    Protection Class: IP20 Rated Frequency: 50/60
    Rated Voltage: 230/400 Proyection Class: IP20
    High Light:

    rcd residual current device

    ,

    rcd controlled circuits switch

    SFL5-63 series Residual Current Device Earth Leakage 2P,4P ,16A ,20A ,25A , 32A , 40A , 63A RCCB

     

     

    The residual current device(RCD) works with no extra power supply to the operating mechanism. It compares the magnitude of the currents through the neutral and phase conductors. The conductors are coiled on toroid and together with the secondary winding form a measurement transformer. The power conductors are coiled in such a way that the magnetic fields generated at electrical current flow through them are mutually neutralized. At failure in the insulation of some of the conductors or at presence of a person under voltage, the system is misbalanced and the magnetic fields can not be neutralized. This residual field generates in the secondary current winding, called current leakage. The device breaks when the value of this current exceeds the limit value of the RCD. Every people from any profession and any cultural level are in close contact with electrical energy at any hour of the day and they may encounter residual currents. Under normal conditions, benefits from electrical energy are countless. However, damages arising from an insulation error are also really huge.

     

     

     

    type In/A I△n/A Residual Current (I△)Is Corresponding To The Following Breaking Time
    I△n 2I△n 5I△n 5A ,10A ,20A ,50A ,100A ,200A ,500A  

    general

    type

    any

    value

    any

    value

    0.3 0.15 0.04 0.04 Max Break-time
    S type ≥25 >0.03 0.5 0.2 0.15 0.15 Max Break-time
    0.13 0.06 0.05 0.04 Min non-driving time
    G type

    any

    value

    any

    value

    0.5 0.2 0.15 0.15 Max Break-time
    0.01 0.01 0.01 0.01 Min Non-driving time
    The general type RCBO whose current I△n is 0.03mA or less can use 0.25A instead of 5I△n

     

     

     

    Type Tripping current I△/A
    AC 0.5I△n<I△<I△n
    A Lagging Angle I△n>0.01A I△n≤0.01A
    0 0.35I△n≤I△≤1.4I△n 0.35I△n≤I△n≤2I△n
    90 0.25I△n≤I△≤1.41I△n 0.25I△n≤I△≤2I△n
    135 0.11I△n≤I△≤1.4I△n 0.11I△n≤I△≤2I△n